Semi Automatic Rotary Bottle Washing Machine
- Home
- Bottle Washing Machines
- Semi Automatic Rotary Bottle Washing Machine






TECHNICAL SPECIFICATIONS. |
|||
Output* |
30-60 BPM @ 500 ml glass round bottle |
||
No .of Container Holder |
64 |
||
Direction of Machine** |
Clock wise |
||
Electrical Specifications** |
Main Motor |
0.5 HP / 415 Volts / 50 Hz |
|
Pump Two Nos. |
1 HP x 2 = 2 HP / 415 Volts / 50 Hz |
||
Electrical Heater |
3 Kw. |
||
Tank Capacity |
75 Ltrs. S.S. 304 (2 Nos.) |
||
Wash Cycle |
4 Inner + 1 Outer (Inner wash sequence are inter changeable) |
||
Height of machine plate |
860 to 910 mm |
||
Machine Dimensions (LxWxH)** |
1850 mm X 1850 mm X 1820 mm |
||
Net Weight |
500 Kgs. |
||
Gross Weight |
750 Kgs. |
||
Change parts required |
(A) Neck Dia: Bottle holding pocket. |
||
Input Specifications |
|||
Round Shape*** |
(A) Ø 30 mm to Ø 100 mm (B) 150 mm to 360 mm (Height option for other bottle height available) |
||
* Depends on bottle size & operator speed. ** Can be customized. *** With help of change parts. |
|||
Consumption of Water |
|||
First Wash |
230 Ltrs./Hr. |
||
Second Wash |
No consumption as such, water loss during re-circulation shall be compensated |
||
Third Wash |
230 Ltrs./Hr. |
||
Fourth Wash |
No consumption as such, water loss during re-circulation shall be compensated OR Air Wash |
||
Outside Wash |
200 Ltrs./Hr. |
||
Salient Features |
|||
· Geneva Mechanism. · Four inner (Included one air wash) & one outer. · Sequence of washes to customer’s choice. · Easy operation. · Stationary nozzles eliminate contamination of water cycles. · Easy loading and unloading. · Individual solenoid valve for each washing sequence, that eliminates carbon plate and other accessories reduce leakage and maintenance to minimum. · Higher capacity centrifugal pumps to wash bigger bottles (500 & 1000 ml.). · The stationary nozzles avoid chipping of bottle necks. · Pumps and tanks are mounted on portable stand for easy maintenance. · Bottle guide system especially for lightweight bottle. · Pumps and Tanks are mounted on Portable stand for Easy Maintenance. · Separate panel control to avoid any short circuit due to spraying of water. · S.S. glycerin fill pressure meter. |
|||
Utility Requirement |
|||
Electrical supply |
3 Phase + Neutral + Earthing |
||
Electrical load |
2 KW + 3 KW for Heater |
||
Air Pressure: Minimum |
6 bar pressure 5 CFM |